Description
Technical Specifications
Insulation Thickness | Insulation Density | Insulation Thickness Painted Galvanized Sheet / Painted Aluminum |
Thermal Conductivity Coefficient | Fire Class |
40 – 50 – 60 – 80 – 100 – 120 mm | PUR 38-40 (±2) kg/m3 PIR 38-42 (±2) kg/m3 |
External Surface 0,45 – 0,50 – 0,60 – 0,70 mm Inner Surface 0,35 – 0,40 – 0,50 – 0,60 – 0,70 mm |
Λ = 0,022 W/mK(EN 13165) | PUR B-s2, d0 EN 13501-1 PUR C-s2, d0 EN 13501-1 PIR B-s1, d0 EN 13501-1 PUR B-s2, d0 EN 13501-1 |
Water Absorption | Vapour Diffusion Resistance | Closed Cell Ratio | Dimensional Stability | Paint Types |
Hacimce %2 (168 saat)(EN ISO 354) | 30-100(EN 12086) | %95(EN 14509) | Seviye DS (TH) 11 | Polyester, PVDF, Plastisol ve PVC Kaplama |
Load Carrying Table
EMAY SMART 3H DV | |||||||||
INSULATION FILLING | INSULATION FILLING THICKNESS mm | TOP SHEET mm | BOTTOM SHEET mm | MULTIPLE APERTURE mm | HEAT PERMEABILITY U VALUE (W/m²K) |
HEAT RESISTANCE R VALUE (m²K/W) |
|||
1000 mm | 1500 mm | 2000 mm | 2500 mm | ||||||
PUR / PIR | 40 | 0,50 | 0,40 | 348 | 202 | 145 | 112 | 0,55 | 1,82 |
50 | 0,50 | 0,40 | 423 | 253 | 182 | 142 | 0,44 | 2,27 | |
60 | 0,50 | 0,40 | 383 | 295 | 214 | 169 | 0,37 | 2,73 |
· The material is adopted as DX-51.
· Deflection Limit was calculated as L/200.
· Calculation was made according to safety stress management.
· The carrying load values in the table do not include point or linear loads.
· The carrying load values in the table give the uniformly distributed load. kg/m2
· The values given in the table are approximate calculations and are shared to give an idea. Emay Panel reserves the right to change the data in the table.