Description
Yük Taşıma Tablosu
EMAY SMART 5H DVT PVC/TPO MEMBRAN | |||||
INSULATION FILLING | TOP MEMBRAN mm | BOTTOM SHEET mm | MULTIPLE APERTURE mm | ||
1000 mm | 1500 mm | 2000 mm | |||
ROCK WOOL | 1,20 | 0,50 | 221 | 145 | 111 |
1,20 | 0,60 | 266 | 174 | 141 | |
1,20 | 0,70 | 308 | 204 | 155 |
• The material is adopted as DX-51.
• Deflection Limit was calculated as L/200.
• Calculation was made according to safety stress management.
• The carrying load values in the table do not include point or linear loads.
• The carrying load values in the table give the uniformly distributed load. kg/m2
• The values given in the table are approximate calculations and are shared to give an idea. Emay Panel reserves the right to change the data in the table.
• For more detailed information, please contact Emay Panel quality unit.